The main function of gutter cover is to facilitate the passage of pedestrians and vehicles and to block the evaporation of waste water and exhaust gas in the gutter. There are three kinds of common di

The main function of gutter cover is to facilitate the passage of pedestrians and vehicles and to block the evaporation of waste water and exhaust gas in the gutter. There are three kinds of common ditch cover materials: cement, metal and fiberglass. Next, I will introduce the FRP trench cover plate.

Forming process of FRP trench cover plate

Glass fiber reinforced plastic trench cover plate, also known as glass fiber reinforced plastic grid plate, is molded by high-temperature molding process. It has the characteristics of two-way isotropy in the vertical and horizontal directions. There is also a closed type of glass fiber reinforced plastic trench cover plate, which is also molded by high-temperature molding process, and then a skin process will be carried out later, which is called glass fiber reinforced plastic cover plate in the industry.

 

[model and parameters of GRP trench cover plate]

When consulting with the fiberglass grating for the cover plate of the fiberglass trench, the manufacturer will usually say how about the 25-38. In fact, the 25-38 here refers to the specification and model of the fiberglass grating. Here is a detailed introduction:

25 specification: thickness (mm): 25 aperture size (mm): 38 * 38 standard size (mm): 1220 * 3660 bearing capacity is about 1 ton.

 

30 specification: thickness (mm): 30 aperture size (mm): 38 * 38 standard size (mm): 1220 * 3660 bearing capacity is about 3 tons.

38 specification: thickness (mm): 38 aperture size (mm): 38 * 38 standard size (mm): 1220 * 3660 bearing capacity is about 6 tons.

50 specification: thickness (mm): 50 aperture size (mm): 50 * 50 standard size (mm): 1220 * 3660 bearing capacity is about 9 tons.

The specification of the FRP cover plate is the same as that of the FRP grid, but the corresponding specification is 2mm more. For example, the specification of FRP grid is 25 / 30 / 38 / 50 / 60 / 70, while that of FRP cover plate is 27 / 32 / 40 / 52 / 62 / 72.

 

Many customers think that as long as the trench is covered with GRP cover plate, they will not need to worry about it. In fact, even if the trench is covered with GRP grid, they should clean it regularly, which not only can increase the service life of GRP cover plate grid, but also can prevent the trench from blocking.